DC-AC INVERTER UNIT
CXA-0308 (8W DUAL OUTPUTS WITH DIMMING FUNCTION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbol
Output Current
Iout1 /
Iout2
Input Current 1
Iin1
Input Current 2
Iin2
Frequency
F1
Frequency (Duty) F2
Open Voltage
Vopen
Alarm SIgnal
Vst
(Note 4)
Vin (V)
12 ± 1.2
12 ± 0.6
12 ± 0.6
12 ± 0.6
12 ± 0.6
12 ± 0.6
12 ± 0.6
10.8
12 ± 1.2
12 ± 1.2
12 ± 1.2
Conditions
Vrmt (V) Vbr / VR
Ta (°C )
5 ± 0.25
0V / 0Ω
-10 ~ +70
5 ± 0.25
0V / 0Ω
23 ± 5
5 ± 0.25 2.5V / 50kΩ
23 ± 5
5 ± 0.25
0V / 0Ω
-10 ~ +70
0 ± 0.25
0V / 0Ω
-10 ~ +70
5 ± 0.25
0V / 0Ω
-10 ~ +70
5 ± 0.25 2.5V / 50kΩ -10 ~ +70
5 ± 0.25
0V / 0Ω
-10 ~ +70
5 ± 0.25
0V / 0Ω
-10 ~ +70
5 ± 0.25
0V / 0Ω
-10 ~ +70
5 ± 0.25
0V / 0Ω
-10 ~ +70
RL1 (kΩ) // CL1(pF)
RL2 (k Ω) // CL2(pF)
95 ~ 105 // 5
95 ~ 105 // 5
100 // 5
100 // 5
95 ~ 105 // 5
95 ~ 105 // 5
100 // 5
100 // 5
95 ~ 105 // 5
95 ~ 105 // 5
95 ~ 105 // 5
95 ~ 105 // 5
95 ~ 105 // 5
95 ~ 105 // 5
∞
∞
95 ~ 105 // 5
∞
∞
95 ~ 105 // 5
95 ~ 105 // 5
95 ~ 105 // 5
Specifications
Unit
Note
min.
t y p.
max.
4.3
5.0
5.7 mArms
Max Brightness.
4.5
5.0
5.5 mArms
1.8
2.5
3.2 mArms Min Brightness.
-
0.55
0.9
Adc
-
-
1
mAdc
50
55
60
kHz
220
250
280
Hz
1200 1250 1500 Vrms
4.5
5.0
5.5
Vdc RL2 // CL2 open
4.5
5.0
5.5
Vdc RL1 // CL1 open
-
0
0.5
Vdc
Normal
Note 1 :
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on
mechanical drawing and any conductors.
Note 2 :
Open circuit on all lamps for more than 3 seconds, will shut the inverter down.
TEST CIRCUIT :
Vin
10.8~13.2V
A Iin
V
F
F
CN1-1
CN1-2
1000:1
PROBE
CN2-3
SW3
Vopen
V
~
CN1-3
CN1-4
SW4
Vrmt
0/5V
V
a
b SW1
T1
CN2-2
Q6
C10
CN1-5
C25
RL2 RL1
CL2
CL1
A
A
~
~
a
Iout2 Iout1
Vbr
CN1-6
0~2.5V
V
b SW2
CN2-1
SW5
Rbr
CN1-7
0~50k
CN1-8
V
Vst
SW1
a
b
SW2
a
b
Operation of unit
Operation
Non operation
Operation of unit
Voltage dimming
Vbr=0~2.5V
Variable resistance dimming
VR=0~50k Ω
Note 3:
In test circuit; 5pF capacitor across the load resistor is add to simulate LCD back-light stray capacitor.
Note 4 :
In test circuit; if any of switches SW3, Sw4 or SW5 opens , then the alarm signal will be activated (+5V).
General Information
Tel : +81-3-5201-7206
Tel : +1-847-390-4439
Tel : +44-118- 921-6206
(Japan)
(USA)
(EU)
All specification are subject to change without notice.
Page ( 2 / 2 )
CXA E VER, 2001/04/23
CTGB8V009-A