LC74794, 74794M
COMMAND3 (Horizontal display start position and horizontal size setup command)
First byte
DA
0 to 7
7
6
5
4
3
2
1
0
Register
—
—
—
—
HS21
HS20
HS11
HS10
State
1
0
1
1
0
1
0
1
0
1
0
1
Contents
Function
Command 3 identification code
Sets the horizontal display start position and the horizontal character size.
HS21 HS20
0
1
HS11 HS10
0
1
0
1Tc/dot
3Tc/dot
0
1Tc/dot
3Tc/dot
1
2Tc/dot
1Tc/dot
1
2Tc/dot
1Tc/dot
Notes
Second line horizontal character size
First line horizontal character size
Second byte
DA
0 to 7
7
6
5
4
3
2
1
0
Register
—
—
HP5
(MSB)
HP4
HP3
HP2
HP1
HP0
(LSB)
State
0
0
0
1
0
1
0
1
0
1
0
1
0
1
Contents
Function
Second byte identification bit
If HS is the horizontal start position then:
5
HS
=
Tc
×
(2
n
Σ
=
2n
0
HPn)
Tc: Period of the oscillator connected to OSCIN/OSCOUT in operating
mode.
Note: All registers are set to 0 when the LC74794/M is reset by the RST pin.
Notes
The horizontal display start position is set by
the 6 bits HP0 to HP5.
The weight of bit 1 is 2Tc.
No. 5557-11/30