CY7C1061AV33
Maximum Ratings
Exceeding maximum ratings may shorten the useful life of the
device. These user guidelines are not tested.
Storage Temperature ............................... –65 C to +150 C
Ambient Temperature with
Power Applied ......................................... –55 C to +125 C
Supply Voltage on
VCC to Relative GND [5] ...............................–0.5 V to +4.6 V
DC Voltage Applied to Outputs
in High Z State [5] ................................ –0.5 V to VCC + 0.5 V
DC Input Voltage [5] ............................ –0.5 V to VCC + 0.5 V
Current into Outputs (LOW) ........................................ 20 mA
Operating Range
Range
Commercial
Industrial
Ambient Temperature
0 C to +70 C
–40 C to +85 C
VCC
3.3 V 0.3 V
DC Electrical Characteristics
Over the Operating Range
Parameter
Description
Test Conditions
VOH
Output HIGH Voltage
IOH = –4.0 mA
VOL
Output LOW Voltage
IOL = 8.0 mA
VIH
Input HIGH Voltage
VIL
Input LOW Voltage [5]
IIX
Input Leakage Current
GND < VI < VCC
IOZ
Output Leakage Current
GND < VO < VCC, Output Disabled
ICC
VCC Operating Supply Current VCC = max, f = fmax = 1/tRC
Commercial
Industrial
ISB1
Automatic CE Power-down
Current – TTL Inputs
CE2 < VIL, Max VCC, CE > VIH,
VIN > VIH or VIN < VIL, f = fmax
ISB2
Automatic CE Power-down
Current – CMOS Inputs
CE2 < 0.3 V, Max VCC,
Commercial
/ Industrial
CE > VCC – 0.3 V,
VIN > VCC – 0.3 V, or VIN < 0.3 V,
f=0
-10
Unit
Min
Max
2.4
–
V
–
0.4
V
2.0
–0.3
VCC + 0.3 V
0.8
V
–1
+1
A
–1
+1
A
–
275
mA
–
275
mA
–
70
mA
–
50
mA
Note
5. VIL(min) = –2.0 V for pulse durations of less than 20 ns.
Document Number: 38-05256 Rev. *L
Page 5 of 17