SEME
LAB
2N3019CSM
ELECTRICAL CHARACTERISTICS (Tcase = 25°C unless otherwise stated)
Parameter
Test Conditions
Min.
V(BR)CEO* Collector – Emitter BreakdownVoltage IC = 10mA IB = 0
80
V(BR)CBO* Collector – Base Breakdown Voltage IC = 100µA IE = 0
140
V(BR)EBO* Emitter – Base Breakdown Voltage
IE = 100µA IC = 0
7
ICBO
Collector Cut-off Current
VCB = 90V
VBE = 0
Tamb = 150°C
IEBO
Emitter Cut-off Current
VEB = 5V
VCE(sat)*
Collector – Emitter Saturation Voltage IC = 150mA
IC = 500mA
IB = 15mA
IB = 50mA
VBE(sat)* Base – Emitter Saturation Voltage
IC = 150mA IB = 15mA
IC = 0.1mA VCE = 10V
50
IC = 10mA VCE = 10V
90
IC = 150mA VCE = 10V
100
hFE*
DC Current Gain
Tamb = –55°C 40
IC = 500mA VCE = 10V
50
IC = 1A
VCE = 10V
15
t* Pulse test tp = 300µs , δ ≤ 2%
DYNAMIC CHARACTERISTICS (Tcase = 25°C unless otherwise stated)
Parameter
Test Conditions
Min.
fT
Transition Frequency
IC = 50mA VCE = 10V f = 20MHz
100
CEBO
Capacitance
VEB = 0.5V IC = 0
f = 1.0MHz
CCBO
Input Capacitance
VCB = 10V IE = 0
f = 1.0MHz
hfe
Small Signal Current Gain IC = 1mA VCE = 5V f = 1kHz
80
NF
Noise Figure
IC = 100µA VCE = 10V f = 1kHz
Rg = 1KΩ
Typ.
Typ.
Max. Unit
V
V
V
10
nA
10
µA
10
nA
0.20
0.50
V
1.1
—
300
Max.
60
12
400
Unit
MHz
pF
pF
—
4
dB
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
Document Number 5468
E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Issue 1