BD6883GUL,BH6453GUL,BD6886GUL,BD6369GUL
Technical Note
●Absolute Maximum Ratings (Ta=+25°C)
Parameter
Symb
ol
BD6883GUL
Limit
BH6453GUL
BD6886GUL
BD6369GUL
Unit
Power supply voltage
VCC
-0.5 to +6.5
-0.5 to +4.5
-0.5 to +6.5
-0.5 to +6.5
V
Motor power supply voltage VM
-
-
-0.5 to +6.5
-0.5 to +6.5
V
Control input voltage
VIN -0.5 to VCC+0.5 -0.5 to VCC+0.5 -0.5 to VCC+0.5 -0.5 to VCC+0.5 V
Input voltage for
Constant-Voltage setting
VLIM -0.5 to VCC+0.5
-
-0.5 to VM+0.5 -0.5 to VM+0.5
V
Input voltage for
Constant-Current setting
Power dissipation
CLIM
Pd
-
510※1
-0.5 to VCC+0.5
430※2
-
730※3
-
V
730※3
mW
Operating
temperature range
Topr
-25 to +85
-25 to +85
-25 to +85
-25 to +85
°C
Junction temperature
Tjmax
+150
+125
+150
+150
°C
Storage temperature range Tstg
-55 to +150
-55 to +125
-55 to +150
-55 to +150
°C
H-bridge output current
Iout -200 to +200※4 -300 to +300※5 -200 to +200※4 -500 to +500※4 mA
※1 Reduced by 4.08mW/°C over 25°C, when mounted on a glass epoxy board (50mm 58mm 1.75mm; 8 layers).
※2 Reduced by 4.30mW/°C over 25°C, when mounted on a glass epoxy board (50mm 58mm 1.75mm; 8 layers).
※3 Reduced by 5.84mW/°C over 25°C, when mounted on a glass epoxy board (50mm 58mm 1.75mm; 8 layers).
※4 Must not exceed Pd, ASO, or Tjmax of 150°C.
※5 Must not exceed Pd, ASO, or Tjmax of 125°C.
●Operating Conditions
Parameter
Symbol BD6883GUL
Limit
BH6453GUL
BD6886GUL
BD6369GUL
Unit
Power supply voltage
VCC
+2.5 to +5.5
+2.3 to +3.6
+2.5 to +5.5
+2.5 to +5.5
V
Motor power supply voltage VM
-
-
+2.5 to +5.5
+2.5 to +5.5
V
Control input voltage
VIN
0 to VCC
0 to VCC
0 to VCC
0 to VCC
V
Input voltage for
Constant-Voltage setting
VLIM
0 to VCC
-
0 to VM
0 to VM
V
Input voltage for
Constant-Current setting
H-bridge output current
CLIM
-
0 to VCC
-
-
V
Iout
-150 to +150※6 -200 to +200※6 -150 to +150※6
-400 +400※6
mA
※6 Must not exceed Pd or ASO.
●Power Dissipation Reduction
510
430
265
172
0 25
85
150
Ambient Temperature:Ta[°C]
Fig.1 BD6883GUL Power Dissipation Reduction
730
0 25
85 125
Ambient Temperature:Ta[°C]
Fig.2 BH6453GUL Power Dissipation Reduction
730
380
380
0 25
85
150
Ambient Temperature:Ta[°C]
Fig.3 BD6886GUL Power Dissipation Reduction
0 25
85
150
Ambient Temperature:Ta[°C]
Fig.4 BD6369GUL Power Dissipation Reduction
www.rohm.com
© 2012 ROHM Co., Ltd. All rights reserved.
2/16
2012.03 - Rev.A