STGW39NC60VD
Electrical characteristics
Table 6. Switching on/off (inductive load)
Symbol
Parameter
Test conditions
td(on)
tr
(di/dt)onf
Turn-on delay time
Current rise time
Turn-on current slope
td(on)
tr
(di/dt)on
Turn-on delay time
Current rise time
Turn-on current slope
tr(Voff)
td(off)
tf
Off voltage rise time
Turn-off delay time
Current fall time
tr(Voff)
td(off)
tf
Off voltage rise time
Turn-off delay time
Current fall time
VCC = 390 V, IC = 30 A,
RG=10 Ω, VGE = 15 V
(see Figure 18)
VCC = 390 V, IC = 30 A,
RG=10Ω, VGE=15 V
TC=125 °C
(see Figure 18)
VCC = 390 V, IC = 30 A,
RG=10 Ω, VGE=15 V
(see Figure 18)
VCC = 390 V, IC = 30 A,
RG=10 Ω, VGE=15 V
TC=125 °C
(see Figure 18)
Min. Typ. Max. Unit
33
13
2500
ns
ns
A/µs
32
14
2280
ns
ns
A/µs
33
ns
178
ns
65
ns
68
ns
238
ns
128
ns
Table 7. Switching energy (inductive load)
Symbol
Parameter
Test conditions
Min Typ. Max Unit
Eon (1)
Eoff(2)
Ets
Eon (1)
Eoff (2)
Ets
Turn-on switching losses
Turn-off switching losses
Total switching losses
Turn-on switching losses
Turn-off switching losses
Total switching losses
VCC = 390V, IC = 30A
RG= 10Ω, VGE= 15V,
(see Figure 20)
VCC = 390V, IC = 30A
RG= 10Ω, VGE= 15V,
TC= 125°C
(see Figure 20)
333
µJ
537
µJ
870
µJ
618
µJ
1125
µJ
1743
µJ
1. Eon is the turn-on losses when a typical diode is used in the test circuit in figure 2 Eon include diode
recovery energy. If the IGBT is offered in a package with a co-pak diode, the co-pack diode is used as
external diode. IGBTs & Diode are at the same temperature (25°C and 125°C)
2. Turn-off losses include also the tail of the collector current