Philips Semiconductors
Dual retriggerable monostable multivibrator
with reset
Product specification
74AHC123A;
74AHCT123A
SYMBOL PARAMETER
TEST CONDITIONS
WAVEFORMS
CL
Tamb (°C)
25
40 to +85 40 to +125 UNIT
MIN. TYP. MAX. MIN. MAX. MIN. MAX.
VCC = 4.5 to 5.5 V; note 2
tW
trigger pulse
see Fig 8
width; nA = LOW
50 pF 5.0 − −
5.0
5.0
ns
trigger pulse
see Fig 8
width; nB = HIGH
5.0 − −
5.0
5.0
ns
reset pulse width;
nRD = LOW
output pulse
width; nQ = HIGH;
nQ = LOW
see Fig 9
CEXT = 28 pF;
REXT = 2 k;
note 3; see Figs 8,
9 and 10
5.0 − −
5.0
5.0
ns
100 200
240
240 ns
CEXT = 0.01 µF;
REXT = 10 k;
note 3; see
Figs 8, 9 and 10
90 100 110 90 110 85 115 µs
CEXT = 0.1 µF;
REXT = 10 k;
note 3; see Figs 8,
9 and 10
0.9 1 1.1 0.9 1.1 0.85 1.15 ms
trt
retrigger time;
CEXT = 100 pF;
nA to nB
REXT = 1 k; see
Figs 8, 9 and 10
39
ns
CEXT = 0.01 µF;
REXT = 1 k; see
Figs 8, 9 and 10
1.2
µs
Notes
1. Typical values are measured at VCC = 3.3 V and Tamb = 25 °C.
2. Typical values are measured at VCC = 5.0 V and Tamb = 25 °C.
3. For CEXT 10 nF the typical value of the pulse width tW (µs) = REXT (k) × CEXT (nF).