Si7005
Table 5. Temperature Sensor
2.1 VDD 3.6 V; TA = 0 to 70 °C (F grade) or –40 to +85 °C (G grade); tCONV = 35 ms unless otherwise noted.
Parameter
Operating Range
Resolution1
Symbol
Test Condition
Min Typ Max
–40
—
85
—
—
14
Accuracy2
Typical at 25 °C
—
—
1/32
—
±0.5 ±1.0
Maximum
See Figure 3.
Repeatability—Noise
—
0.1
—
Response Time3
Time to reach 63% of final value
—
1.5
—
Long Term Stability
— <0.05
—
Notes:
1. The Si7005 has a nominal output of 32 codes /°C, with 0000 = –50 °C
2. Temperature sensor accuracy is for VDD = 2.3 to 3.6 V.
3. Actual response times will vary dependent on system thermal mass and air-flow.
Unit
°C
Bit
°C
°C
°C
°C
RMS
s
°C/yr
TemperatureAccuracy
Max.TError(°C)
Typ.TError(°C)
4
3.5
3
2.5
2
1.5
1
0.5
0
Temperature(°C)
Figure 3. Temperature Accuracy
8
Rev. 1.3