AD7886
BIPOLAR OFFSET AND GAIN ADJUSTMENT
In applications where absolute accuracy is important, offset and
gain error can be adjusted to zero. Offset is adjusted by trim-
ming the voltage at the VIN1 or VIN2 input when the analog in-
put is at zero volts. This can be achieved by adjusting the offset
of an external amplifier used to drive either of these inputs (see
A1 in Figure 9). The trim procedure is as follows:
Apply zero volts at AIN and adjust the offset of A1 until the
ADC output code flickers between 0111 1111 1111 and 1000
0000 0000.
Gain error can be adjusted at either the first code transition
(ADC negative full scale) or the last code transition (ADC posi-
tive full scale). Adjusting the reference, as in Figure 9, will trim
the positive gain error only. The trim procedure is as follows:
Apply a voltage of 4.99756 V, (FS/2–1 LSB) at AIN and
adjust R3 until the output code flickers between 1111 1111
1110 and 1111 11111111.
If the first code transition needs adjusting, a gain trim must be
included in the analog signal path. The trim procedure will then
consist of applying an analog signal of –4.99756 V (–FS/2+1 LSB)
and adjusting the trim until the output code flickers between
0000 0000 0000 and 0000 0000 0001.
AIN
AD845
+
± 5V
A1
+ 5V
VDD
VIN1
VIN2
+V
+VIN
VOUT
AD586
GND
+ 5V
R1
82k
R3
5k
AGND
+ 5REF
AD707
–3.5V
+
SUM
VREF
R2
56k
C1
C2
10µF 0.1µF
AD7886*
VSS
– 5V
*ADDITIONAL PINS OMITTED FOR CLARITY
Figure 9. Bipolar Operation with Gain Error Adjust
TIMING AND CONTROL
Conversion start is controlled by the CONVST input (see Fig-
ures 10 and 11). A high to low going edge on the CONVST in-
put puts the track/hold amplifier into the hold mode. The ADC
conversion procedure does not begin until a rising CONVST
pulse edge occurs. The width of the CONVST pulse low time
determines the track-to-hold settling time. The BUSY output,
which indicates the status of the ADC, goes low while conver-
sion is in progress. At the end of conversion BUSY returns high,
indicating that new data is available on the AD7886’s output
latches. The track/hold amplifier returns to the track mode at
the end of conversion and remains there until the next
CONVST pulse. Conversion starts must not be attempted while
conversion is in progress as this will cause erroneous results.
Data read operations are controlled by the CS and RD inputs.
These digital inputs, when low, enable the AD7886’s three-
state output latches. Note, these latches cannot be enabled dur-
ing conversion. In applications where CS and RD are tied per-
manently low, as in Figure 11, the data bus will go into the
three-state condition at the start of conversion and return to its
active state when conversion is complete. Tying CS and RD
permanently low is useful when external latches are used to
store the conversion results. The data bus becomes active before
BUSY returns high at the end of conversion, so that BUSY can
be used as a clocking signal for the external latches.
A typical DSP application would have a timer connected to the
CONVST input for precise sampling intervals. BUSY would be
connected to the interrupt of a microprocessor that would be
asserted at the end of every conversion. The microprocessor
would then assert the CS and RD inputs and read the data from
the ADC. For applications where both data reading and conver-
sion control need to be managed by a microprocessor, a CONVST
pulse can be decoded from the address bus. One decoding pos-
sibility is that a write instruction to the ADC address starts a
conversion, and a read instruction reads the conversion result.
TRACK-TO-HOLD
TRANSITION
CONVST
CS
RD
BUSY
DATA
t1
t5
t13
CONVERSION
START
HOLD TO
TRACK
TRANSITION
t11
t CONV
t6
HIGH IMPEDANCE
t12
t10
t2
t3
t4
t7
DATA
VALID
Figure 10. Conversion Start and Data Read Timing
Diagram
CONVST
TRACK-TO-HOLD
TRANSITION
t 13
t1
CONVERSION
START
t 12
t5
t CONV
BUSY
DATA
t9
t8
HIGH IMPEDANCE
HOLD TO TRACK
TRANSITION
DATA
VALID
Figure 11. Conversion Start and Data Read
Timing Diagram, (CS = RD = 0 V)
–8–
REV. B