Data Sheet
ADuM2250/ADuM2251
PACKAGE CHARACTERISTICS
Table 3.
Parameter
Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input to Output)1
RI-O
Capacitance (Input to Output)1
CI-O
1012
Ω
2.2
pF
f = 1 MHz
Input Capacitance
CI
4.0
pF
IC Junction to Ambient Thermal Resistance θJA
45
°C/W Thermocouple located at center of
package underside
1 The device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
REGULATORY INFORMATION
The ADuM2250/ADuM2251 are approved by the organizations listed in Table 4.
Table 4.
UL
Recognized Under
UL 1577 Component
Recognition Program1
Single Protection,
5000 V rms Isolation
Voltage
File E214100
CSA
Approved under CSA Component
Acceptance Notice 5A
Basic insulation per CSA 60950-1-07
and IEC 60950-1, 600 V rms
(849 V peak) maximum
working voltage
RW-16 package: reinforced
insulation per CSA 60950-1-07 and
IEC 60950-1, 380 V rms (537 V peak)
maximum working voltage
Reinforced insulation per
IEC 60601-1, 125 V rms (176 V peak)
maximum working voltage
RI-16-2 package: reinforced
insulation per CSA 60950-1-07 and
IEC 60950-1, 400 V rms (565 V peak)
maximum working voltage
Reinforced insulation per
IEC 60601-1, 250 V rms (353 V peak)
maximum working voltage
File 205078
CQC
Approved under CQC11-471543-2012
Basic insulation per GB4943.1-2011,
600 V rms (848 V peak) maximum
working voltage, tropical climate,
altitude ≤ 5000 m
RW-16 package: reinforced insulation
per GB4943.1-2011, 380 V rms (537 V peak)
maximum working voltage,
tropical climate, altitude ≤ 5000 m
RI-16 package: reinforced insulation
per 400 V rms (565 V peak) maximum
working voltage, tropical climate,
altitude ≤ 5000 m
File CQC14001117251
VDE
Certified according to
DIN V VDE V 0884-10
(VDE V 0884-10):2006-122
Reinforced insulation,
849 V peak
File 2471900-4880-0001
1 In accordance with UL 1577, each ADuM2250/ADuM2251 is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec (current leakage detection limit = 10 μA).
2 In accordance with DIN V VDE V 0884-10 (VDE V 0884-10):2006-12, each ADuM2250/ADuM2251 is proof tested by applying an insulation test voltage ≥ 1590 V peak for 1 sec
(partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 5.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Symbol
L(I01)
Minimum External Tracking (Creepage)
L(I02)
RW-16 Package
RI-16-2 Package
Minimum Internal Distance (Internal Clearance)
Tracking Resistance (Comparative Tracking Index) CTI
Isolation Group
Value
5000
8.0 min
Unit
V rms
mm
7.7 min mm
8.3 min mm
0.017 min mm
>400
V
II
Test Conditions/Comments
1-minute duration
Distance measured from input terminals to output
terminals, shortest distance through air along the
PCB mounting plane, as an aid to PC board layout
Measured from input terminals to output
terminals, shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303, Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)