OPI1264 Series
ABSOLUTE MAXIMUM RATINGS (25 °C unless otherwise noted)
INPUT DIODE
FORWARD DC CURRENT
REVERSE DC VOLTAGE
POWER DISSIPATION
OUTPUT PHOTOTRANSISTOR
COLLECTOR-EMITTER VOLTAGE
EMITTER-COLLECTOR VOLTAGE
POWER DISSIPATION
OPERATING TEMP
50mA (3)
2V
100mW (4)
30 V
5V
100 mW (5)
-40OC TO +85OC
This
component Pb
is RoHS
compliant
NOTES
1- Measured with input diode leads shorted
together and output leads shorted together.
2- RMA Flux is recommended.Duration can
be extended to 10 sec. max. when flow
soldering.
3 - Derate linearly 0.73 mA/OC above 25OC
4 - Derate linearly 1.67 mW/OC above 25OC
5 - Derate linearly 1.67 mW/OC above 25OC
STORAGE TEMP
INPUT-TO-OUTPUT ISOLATION VOLTAGE
LEAD S0LDERING TEMP (2) 1.6mm from case for 5sec with
soldering iron
-40OC TO +85OC
+10KV DC (1)
240OC
Whilst the devices are capable of
operating continually at the noted
elevated temperatures users should
be aware of the possibility of a
reduction in CTR over long periods
at high temperatures & currents.
SCHEDULE OF LIMITATIONS
EC TYPE EXAMINATION CERTIFICATE No. BAS01ATEX1278U/5
SCHEDULE OF LIMITATIONS
28th September 2012
1 - The Opto Isolator must be mounted on a p.c.b. having a CTI of at least 175 such that creepage and clearance distances are not
impaired. i.e.:- on an uncoated printed circuit board that maintains at least 10mm in air.
2 - The Opto Isolator may be used to provide isolation between either:-
(i) A non-intrinsically safe circuit and an intrinsically safe circuit, (Non IS:IS), where the IS circuit voltage is not greater than
75 Volts peak or d.c..
OR
(ii) Two intrinsically safe circuits (IS:IS), where the sum of the two circuit voltages is not greater than 375 Volts peak or d.c..
3 - The Opto Isolator must be installed such that the connection pins are provided with a degree of protection of at least IP20 where
gasses and vapours may be present. If the Opto Isolator is to be installed where dusts represent a hazard, then it must be
provided with a degree of protection of at least IP54 and the overall apparatus must be appropriately certified for the requirements
for Dusts.
4 - The Opto Isolator must be installed with external power limiting components as specified in EN60079-11:2012, Clause 8.9.2.
CERTIFICATE No.:- IECEx BAS 06.0021U
SCHEDULE OF LIMITATIONS
Date of Issue:- 2012-10-02
1. When used in intrinsically safe apparatus it will be necessary to determine a surface
temperature classification for the opto-isolator:-
ISSUE No.: 4
2. The Opto Isolator must be mounted on a printed circuit board such that creepage and
clearance distances are not impaired.
3. The Opto Coupler must be installed such that the connection pins are provided with a degree of protection of IP20 where
gasses and vapours may be present. If the Opto Coupler is to be installed within apparatus where flammable dusts represent
the hazard then it must be provided with a degree of protection of IP54 and the apparatus must be appropriately certified for
dust hazards.
5 - The Opto Isolator must be installed with external power limiting components as specified in IEC60079-11:2011 Ed 6, Clause 8.9.2.