OM9375
SIMPLIFIED BLOCK DIAGRAM
COMMUTATION TRUTH TABLE
This table shows the Phase Output state versus
the state of the Hall-Effect and Direction Inputs.
Please note that the OM9375 Hall-Effect Inputs
are Grey-encoded; that is, only one input is
allowed to change from one input state to
another at a time.
The commutation coding shown reflects Hall-
Effect sensors that are spaced at 120°
mechanical increments. Also, internal
protection logic disables all three Phase
Outputs when the Hall-Effect Inputs are set to
an illegal condition (i.e. all logic low or all logic
high).
DIGITAL INPUTS
Dir
H1
1
0
1
0
1
0
1
1
1
1
1
1
0
1
0
1
0
1
0
0
0
0
0
0
X
0
X
1
H2
H3
0
1
1
1
1
0
1
0
0
0
0
1
0
1
0
0
1
0
1
0
1
1
0
1
0
0
1
1
PHASE OUTPUTS
A
Hi-Z
Sink
Sink
Hi-Z
Source
Source
Sink
Sink
Hi-Z
Source
Source
Hi-Z
Hi-Z
Hi-Z
B
Sink
Hi-Z
Source
Source
Hi-Z
Sink
Source
Hi-Z
Sink
Sink
Hi-Z
Source
Hi-Z
Hi-Z
C
Source
Source
Hi-Z
Sink
Sink
Hi-Z
Hi-Z
Source
Source
Hi-Z
Sink
Sink
Hi-Z
Hi-Z
2.1 - 2