PS9613,PS9613L
*1 Typical values at TA = 25 °C.
*2 Test circuit for propagation delay time
Pulse input (IF = 10 mA)
(PW = 10 µs,
Duty cycle = 1/10)
Input
(monitor)
47 Ω
GND
VCC = 15 V
Input
0.1 µF RL = 20 kΩ
VO (Monitor) Output
CL = 100 pF
VTHHL = 1.5 V
tPHL
IF (ON)
50 % IF (ON)
15 V
VTHLH = 2.0 V
tPLH
VOL
CL is approximately which includes probe and stray wiring capacitance.
*3 Test circuit for common mode transient immunity
GL SW IF
BA
VCC = 15 V
VCM 90 %
0.1 µF RL = 20 kΩ
10 %
GND
tr
tf
VO (monitor)
CL = 100 pF
VO
(Switch A: IF = 0 mA)
VO
(Switch B: IF = 10 mA)
1.5 kV
0V
VOH
3.0 V
1.0 V
VOL
CL is approximately which includes probe and stray wiring capacitance.
USAGE CAUTION
By-pass capacitor of more than 0.1 µF is used between VCC and GND near device. Also, ensure that the distance
between the leads of the photocoupler and capacitor is no more than 10 mm.
6
Data Sheet P13981EJ2V0DS00