MOSEL VITELIC
Absolute Maximum Ratings*
Operating temperature range ..................0 to 70 °C
Storage temperature range ............... -55 to 150 °C
Input/output voltage .................. -0.3 to (VCC+0.3) V
Power supply voltage .......................... -0.3 to 4.6 V
Power dissipation ............................................. 1 W
Data out current (short circuit) ...................... 50 mA
*Note: Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage of the device.
Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.
V54C365404VD(L)
Recommended Operation and Characteristics for LV-TTL
TA = 0 to 70 °C; VSS = 0 V; VCC,VCCQ = 3.3 V ± 0.3 V
Limit Values
Parameter
Symbol
min.
max. Unit Notes
Input high voltage
VIH
2.0
Vcc+0.3
V
1, 2
Input low voltage
VIL
– 0.3
0.8
V
1, 2
Output high voltage (IOUT = – 2.0 mA)
VOH
2.4
–
V
Output low voltage (IOUT = 2.0 mA)
VOL
–
0.4
V
Input leakage current, any input
(0 V < VIN < 3.6 V, all other inputs = 0 V)
II(L)
–5
5
µA
Output leakage current
(DQ is disabled, 0 V < VOUT < VCC)
IO(L)
–5
5
µA
Note:
1. All voltages are referenced to VSS.
2. VIH may overshoot to VCC + 2.0 V for pulse width of < 4ns with 3.3V. VIL may undershoot to -2.0 V for pulse width < 4.0 ns with
3.3V. Pulse width measured at 50% points with amplitude measured peak to DC reference.
V54C365404VD(L) Rev. 0.9 September 2001