STV2216
FUNCTIONAL DESCRIPTION
1 - DEFLECTION CIRCUIT (Note : [X,Y] : line number referred to the internal line counter numbering)
- Fully integrated synch. separator, with a low pass
filter, a black level alignment of the Y/CVBS input, a
slicing level at 2/3,1/3of the sync. pulse amplitude.
- Frame sync. pulse locked on 2 fH frequency to
perfect interlace.
- 500kHz VCO with an externalceramic resonator.
- Two phase locked loops
• the first PLL locks the VCO on the video signal
frequency,
• the second PLL compensates the line transistor
storage time.
- Three time constants for the first PLL.
• thelong timeconstantis usedfor normaloperation
• the short time constant is automatically used
during the frame retrace and in search mode of
VCR when the frame pulse is outside [258,264]
and [309,314].
• very long time constant when no video recognition
Time constants in normal operation
(automatic selection of time constants) :
50Hz input signal :
- short time constant : [306, 21]
- long time constant : the rest of the field
60Hz input signal :
- short time constant : [0, 16]
- long time constant : the rest of the field
• inhibition of the first PLL :
the first locked loop is opened from line 309 to
line 4.5 (or 314) in 50Hz mode. It isopened from
line 258 to line 5.5 (or 264) in 60Hz mode.
• the time constantsvalues are chosenby means
of external components.
• possibility to force the short time constant
through the bus.
• possibility to force the very long time constant
through the bus.
- Video identification : coincidence detector be-
tween the line synchro top and a line frequency
window from the firstPLL. The video identification
status is available in the output register of the I2C
bus decoder.
- Generation of burst gate pulses and line fre-
quency signals from the first PLL to drive the
chroma and video circuits. The burst gate pulse
is also sent to the sandcastle generator.
- Frame synchro window : [248, 352] catching
- Field frequency selection windows :
[248, 288] 6 0Hz mo de s ele c tio n if t wo
consecutive frame pulses occur
inside this window,otherwise 50Hz
mode selection.
[288, 352] 50Hz mode selection window
- frame blanking pulse :
from line 0 to 21 in 50Hz mode
from line 0 to 16 in 60Hz mode
- Vertical output pulse is 10.5 lines long.
- Horizontal output pulse : 28µs line pulse on an
open collector output;
- Start up circuit : the horizontal output is at a high
level when VCC increases from 0 to 6.8V. On
shutting down, horizontal pulses are disabled
when VCC is below 6.2V.
- Soft-start circuit : the duty cycle of the horizontal
output is 78 % (Thigh/(Thigh + TLow))when VCC1
is lower than (0.75 x VCC2), during the rising time.
During the falling time, a 78% duty cycle HOUT
pulse is provided when VCC1 is lower than
(0.60 x VCC2).
- Possibility to disable the horizontal output pulse
through the bus (force a high level on HOUT).
- XRAY protection.
- Horizontal position adjustment controlled by bus.
- Bus controlledoutput voltage to adjustthe vertical
amplitude; this voltage permits to adjust the slope
of the vertical sawtooth generated by the external
frame booster.
- Bus controlled vertical position ; the high level of
the vertical pulse permits to adjust the vertical
position.
- Bus controlled 4/3-16/9 selection : the low level
of the vertical pulse is 0.1V when 16/9 is selected,
2V when 4/3 is selected.
- Combined flyback input and sandcastle output
(Pin 37). Two thresholds on LFB/SCO Pin : The
lowest threshold (0.7V) permits to extract the line
blankingpulse; the highestthreshold(2V) permits
to extract the line pulse for PLL2. The sandcastle
signal at Pin 37 is used to control the external
baseband chroma delay line.
3/26