DC Electrical Characteristics (Continued)
Symbol
Parameter
ICCt
Maximum ICC
Per Input
VCC
TA = +25°C
TA = −40°C to +85°C
(V)
Typ
Guaranteed Limits
5.5
2.0
2.0
5.5
2.15
2.15
Note 2: All outputs loaded; thresholds associated with output under test.
Note 3: Maximum test duration 2.0 ms, one output loaded at a time.
Noise Specifications
Units
mA
mA
Conditions
VI = VCC − 2.1V
VI = VCC − 2.1V
TDI/TMS Pin, Test One
with the Other Floating
Symbol
Parameter
VCC
TA = +25°C
TA = −40°C to +85°C
(V)
Typ
Guaranteed Limits
VOLP
Maximum HIGH Output Noise
(Note 5)(Note 6)
5.0
1.0
1.5
VOLV
Minimum LOW Output Noise
(Note 5)(Note 6)
5.0
−0.6
−1.2
VOHP
Maximum Overshoot
(Note 4)(Note 6)
5.0
VOH+1.0 VOH+1.5
VOHV
Minimum VCC Droop
(Note 4)(Note 6)
5.0
VOH−1.0 VOH−1.8
VIHD
Minimum HIGH Dynamic Input Voltage Level
(Note 4)(Note 7)
5.5
1.6
2.0
2.0
VILD Maximum LOW Dynamic Input Voltage Level
(Note 4)(Note 7)
5.5
1.4
0.8
0.8
Note 4: Worst case package.
Note 5: Maximum number of outputs that can switch simultaneously is n. (n − 1) outputs are switched LOW and one output held LOW.
Note 6: Maximum number of outputs that can switch simultaneously is n. (n − 1) outputs are switched HIGH and one output held HIGH.
Note 7: Maximum number of data inputs (n) switching. (n − 1) input switching 0V to 3V. Input under test switching 3V to threshold (VILD).
AC Electrical Characteristics
Units
V
V
V
V
V
V
Symbol
Parameter
tPLH,
Propagation Delay
tPHL
CP to Q
tPLZ,
Disable Time
tPHZ
tPZL,
Enable Time
tPZH
Note 8: Voltage Range 5.0 is 5.0V ± 0.5V.
VCC
(V)
(Note 8)
5.0
5.0
5.0
AC Operating Requirements
Normal Operation
Symbol
Parameter
tS
Setup Time, H or L
Data to CP
tH
Hold Time, H or L
CP to Data
tW
CP Pulse Width
fMAX
Maximum ACP/BCP Clock Frequency
Note 9: Voltage Range 5.0 is 5.0V ± 0.5V.
TA = +25°C
CL = 50 pF
Min
Typ
Max
2.5
9.5
2.5
10.3
1.5
9.0
1.5
9.0
2.0
10.9
2.0
8.9
TA = −40°C to +85°C
CL = 50 pF
Min
Max
2.5
10.5
2.5
11.5
1.5
9.5
1.5
10.0
2.0
12.0
2.0
9.5
Units
ns
ns
ns
VCC
(V)
(Note 9)
5.0
5.0
5.0
5.0
TA = +25°C
TA = −40°C to +85°C
CL = 50 pF
CL = 50 pF
Guaranteed Minimum
3.0
3.0
Units
ns
1.5
1.5
ns
5.0
5.0
ns
100
90
MHz
www.fairchildsemi.com
8