Electrical Characteristics (Cont’d): (VS = 42V, VSS = 5V, TJ = +25°C unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Commutation Frequency
fc (Vi) IL = 2A
−
25 40 kHz
Source Current
Turn−Off Delay
T1 (Ven) 0.5 Ven to 0.9 IL, Note 2
−
3
− μs
Fall Time
Turn−On Delay
Rise Time
Sink Current
Turn−Off Delay
T2 (Ven)
T3 (Ven)
T4 (Ven)
0.9 IL to 0.1 IL, Note 2
0.5 Ven to 0.1 IL, Note 2
0.1 IL to 0.9 IL, Note 2
T5 (Ven) 0.5 Ven to 0.9 IL, Note 2
−
1
− μs
−
o.3 − μs
−
0.4 − μs
−
2.2 − μs
Fall Time
Turn−On Delay
Rise Time
Commutation Frequency
T6 (Ven)
T7 (Ven)
T8 (Ven)
fc (Ven)
0.9 IL to 0.1 IL, Note 2
0.5 Ven to 0.1 IL, Note 2
0.1 IL to 0.9 IL, Note 2
IL = 2A
− 0.35 − μs
− 0.25 − μs
−
0.1 − μs
−
1
− kHz
Note 1. Sensing voltage can be −1V for t ≤ 50μs; in steady state Vsensmin ≥ −0.5V.
Note 2. The load must be a pure resistor.
Note 3. Pin1 and Pin15 connected to GND.
Pin Connection Diagram
(Front View)
15 Current Sensing B
14 Output 4
13 Output 3
12 Input 4
11 Enable B
10 Input 3
9 Logic Supply Voltage VSS
8 GND
7 Input 2
6 Enable A
5 Input 1
4 Supply Voltage VS
3 Output 2
2 Output 1
1 Current Sensing A