● EXPLANATION OF MEASUREMENT CONDITION
PARAMETER
Explanation
Input Offset Voltage Drift
Input Offset Voltage Drift = ∆VIO / ∆t
∆t : Amount of Temperature change.
∆VIO : Amount of Input Offset Voltage.
Common Mode Input Voltage range A range of input voltage at which the operational amplifier can function.
Common Mode Rejection Ratio
Supply Voltage Rejection Ratio
Common Mode Input Impedance
Voltage Gain
CMR = 20log | ( ∆VIN / ∆VIO )|
∆VIN : Amount of Input Voltage.
∆VIO : Amount of Input Offset Voltage.
SVR = 20log |( ∆VS / ∆VIO )|
∆VS : Amount of supply Voltage.
∆VIO : Amount of Input Offset Voltage.
RINCM = ∆VIN / ∆IB
∆VIN : Amount of Input Voltage.
∆IB : Amount of Input bias current.
AV = 20log |( ∆VIN / ∆VO )|
∆VO : Amount of output Voltage.
∆VIN : Amount of Input Voltage.
NJM2729
E1
-5-