MC74LCX240
MAXIMUM RATINGS
Symbol
Parameter
Value
Condition
Units
VCC DC Supply Voltage
−0.5 to +7.0
V
VI
DC Input Voltage
−0.5 VI +7.0
V
VO DC Output Voltage
−0.5 VO +7.0
Output in 3−State
V
−0.5 VO VCC + 0.5
Note 1
V
IIK
DC Input Diode Current
−50
VI < GND
mA
IOK DC Output Diode Current
−50
VO < GND
mA
+50
VO > VCC
mA
IO
DC Output Source/Sink Current
50
mA
ICC DC Supply Current Per Supply Pin
100
mA
IGND DC Ground Current Per Ground Pin
100
mA
TSTG Storage Temperature Range
−65 to +150
C
MSL Moisture Sensitivity
Level 1
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. Output in HIGH or LOW State. IO absolute maximum rating must be observed.
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Min
Typ
Max
Units
VCC Supply Voltage
Operating
Data Retention Only
V
2.0
3.3
3.6
1.5
3.3
3.6
VI
Input Voltage
VO Output Voltage
HIGH or LOW State
3−State
0
5.5
V
V
0
VCC
0
5.5
IOH HIGH Level Output Current, VCC = 3.0 V − 3.6 V
IOL LOW Level Output Current, VCC = 3.0 V − 3.6 V
IOH HIGH Level Output Current, VCC = 2.7 V − 3.0 V
IOL LOW Level Output Current, VCC = 2.7 V − 3.0 V
TA
Operating Free−Air Temperature
−40
Dt/DV Input Transition Rise or Fall Rate, VIN from 0.8 V to 2.0 V, VCC = 3.0 V
0
−24
mA
24
mA
−12
mA
12
mA
+85
C
10
ns/V
ORDERING INFORMATION
Device
Package
Shipping†
MC74LCX240DTR2G
TSSOP−20
(Pb−Free)
2500 Tape & Reel
MC74LCX240DWR2G
SOIC−20 WB
(Pb−Free)
1000 Tape & Reel
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
DC ELECTRICAL CHARACTERISTICS
Symbol
Characteristic
Condition
VIH HIGH Level Input Voltage (Note 2)
VIL LOW Level Input Voltage (Note 2)
VOH HIGH Level Output Voltage
2.7 V VCC 3.6 V
2.7 V VCC 3.6 V
2.7 V VCC 3.6 V; IOH = −100 mA
VCC = 2.7 V; IOH = −12 mA
VCC = 3.0 V; IOH = −18 mA
VCC = 3.0 V; IOH = −24 mA
2. These values of VI are used to test DC electrical characteristics only.
TA = −40C to +85C
Min
Max
2.0
0.8
VCC − 0.2
2.2
2.4
2.2
Units
V
V
V
http://onsemi.com
3