Appendix Standard Serial I/O Mode
Mitsubishi microcomputers
M30201 Group
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
Version Information Output Command
This command outputs the version information of the control program stored in the boot area. Execute
the version information output command as explained here following.
(1) Send the “FB16” command code in the 1st byte of the transmission.
(2) The version information will be output from the 2nd byte onward. This data is composed of 8
ASCII code characters.
y CLK0
r RxD0
FB16
a TxD0
'V'
'E'
'R'
'X'
in P53(BUSY)
Figure DD-10. Timing for version information output
lim Boot Area Output Command
This command outputs the control program stored in the boot area in one page blocks (256 bytes).
Execute the boot area output command as explained here following.
(1) Send the “FC16” command code in the 1st byte of the transmission.
(2) Send addresses A8 to A15 and A16 to A23 in the 2nd and 3rd bytes of the transmission respec-
tively.
e (3) From the 4th byte onward, data (D0–D7) for the page (256 bytes) specified with addresses A8 to
PrA23 will be output sequentially from the smallest address first, in sync with the rise of the clock.
CLK0
RxD0
FC16
A8 to A16 to
A15
A23
TxD0
data0
data255
P53(BUSY)
Figure DD-11. Timing for boot area output
152