Figure 3: Application Circuit (For Other Fixed Output Voltages)
LD1117A SERIES
Table 4: Electrical Characteristics Of LD1117A#12 (refer to the test circuits, TJ = 0 to 125°C, CO = 10
µF, CI = 10 µF, R = 120 Ω between OUT-GND, unless otherwise specified)
Symbol
Parameter
VO Output Voltage
VO Output Voltage
∆VO Line Regulation
∆VO Load Regulation
∆VO Temperature Stability
∆VO Long Term Stability
VI Operating Input Voltage
Id Quiescent Current
IO Output Current
eN Output Noise Voltage
SVR Supply Voltage Rejection
VD Dropout Voltage
∆VO(pwr) Thermal Regulation
Test Conditions
VI = 5.3 V IO = 10 mA
TJ = 25°C
IO = 0 to 1 A
VI = 2.75 to 10 V
VI = 2.75 to 8 V
IO = 0 mA
VI = 2.75 V
IO = 0 to 1 A
1000 hrs, TJ = 125°C
IO = 100 mA
VI ≤ 8 V IO = 0 mA
VI - VO = 5 VTJ = 25°C
B =10Hz to 10KHz TJ = 25°C
IO = 40 mA f = 120Hz
VI - VO = 3 VVripple = 1 VPP
IO = 100 mA
IO = 500 mA
IO = 1 A
Ta = 25°C 30ms Pulse
Min. Typ. Max. Unit
1.176 1.2 1.224 V
1.152 1.2 1.248 V
1
6
mV
1
10
mV
0.5
%
0.3
%
10
V
5
10
mA
1000 1200
mA
100
µV
60
80
dB
1
1.10
V
1.05 1.15
1.15 1.30
0.08 0.2 %/W
3/17