█ Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
Test Sample
NO.
Item
Test Condition
Hours/ Size
Cycle
ITR9606-F
Failure
Judgement
Criteria
Ac/Re
More than
1
Solder Heat
TEMP : 260℃ ± 5 ℃
10 sec
90% of lead to
22 PCs be covered by
0/1
soldering
H : +100℃ 15 min
2 Temperature Cycle
IR≧U×2
5 min
300 22 PCs Ee≦L×0.8
0/1
cycle
VF≧U×1.2
L : -40℃ 15 min
H : +100℃ 5 min
U :Upper
specification
3
Thermal Shock
10 sec
300
limit
22 PCs
0/1
cycle
L :Lower
L : -10℃
5 min
specification
limit
4
High Temperature TEMP. : +100℃
1000 hrs 22 PCs
0/1
Storage
5
Low Temperature TEMP. : -40℃
1000 hrs 22 PCs
0/1
Storage
6
DC Operating Life VCE=5V
1000 hrs 22 PCs
0/1
IF=20mA
7 High Temperature / 85℃ / 85% R.H.
1000 hrs 22 PCs
0/1
High Humidity
Everlight Electronics Co., Ltd.
Device No:CDRX-096-014
http:\\www.everlight.com
Prepared date:2006/12/27
Rev 1
Page: 6 of 7
Prepared by:Kunjiang Xie