DATA SHEET
HAL 5xy
3.2. Dimensions of Sensitive Area
0.25 mm × 0.12 mm
3.3. Positions of Sensitive Areas
SOT89B-1
y 0.95 mm nominal
A4 0.3 mm nominal
D1 see drawing
H1 not applicable
TO92UA-1/-2
1.0 mm nominal
0.3 mm nominal
3.05 mm +/- 0.05 mm
min. 21 mm
max. 23.1 mm
3.4. Absolute Maximum Ratings
Stresses beyond those listed in the “Absolute Maximum Ratings” may cause permanent damage to the device. This
is a stress rating only. Functional operation of the device at these conditions is not implied. Exposure to absolute
maximum rating conditions for extended periods will affect device reliability.
This device contains circuitry to protect the inputs and outputs against damage due to high static voltages or electric
fields; however, it is advised that normal precautions be taken to avoid application of any voltage higher than abso-
lute maximum-rated voltages to this circuit.
All voltages listed are referenced to ground (GND).
Symbol
Parameter
VDD
Supply Voltage
VO
Output Voltage
IO
Continuous Output On Current
TJ
Junction Temperature Range
1)
2)
as long as
t < 1000 h
TJmax is
not
exceeded
Pin No.
1
3
3
Min.
−15
−0.3
−
−40
Max.
281)
281)
501)
1702)
Unit
V
V
mA
°C
3.4.1. Storage and Shelf Life
The permissible storage time (shelf life) of the sensors is unlimited, provided the sensors are stored at a maximum of
30 °C and a maximum of 85% relative humidity. At these conditions, no Dry Pack is required.
Solderability is guaranteed for one year from the date code on the package.
Micronas
Jan. 11. 2010; DSH000020_004EN
13