TIMING DIAGRAMS
0.7 ± 0.1 ns
INPUT
OUTPUT
tPHL
tTLH
0.7 ± 0.1 ns
80%
50%
20%
tPLH
0.95V
1.69V
80%
50%
20%
tTHL
Propagation Delay (Serial Data, Selects)
CEP
tS
D3, Pn, Sn
tS
CLOCK
INHIBIT COUNT
50%
ENABLE COUNT
tH
50%
tH
50%
0.95V
1.69V
0.95V
1.69V
0.95V
1.69V
Set-up and Hold Time
Notes:
1. VEE = 4.2V to 5.5V unless otherwise specified, VCC = VCCA = GND.
2. tS is the minimum time before the transition of the clock that information must be present at the data input.
3. tH is the minimum time after the transition of the clock that information must remain unchanged at the data input.
SY100S336