ADuM3400/ADuM3401/ADuM3402
DIN EN 60747-5-2 (VDE 0884 PART 2) INSULATION CHARACTERISTICS
Table 7.
Description
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤150 V rms
For Rated Mains Voltage ≤300 V rms
For Rated Mains Voltage ≤400 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110, Table 1)
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method b1
VIORM × 1.875 = VPR, 100% Production Test, tm = 1 sec, Partial Discharge < 5 pC
Input-to-Output Test Voltage, Method a
After Environmental Tests Subgroup 1
VIORM × 1.6 = VPR, tm = 60 sec, Partial Discharge < 5 pC
After Input and/or Safety Test Subgroup 2/3
VIORM × 1.2 = VPR, tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage (Transient Overvoltage, tTR = 10 sec)
Safety-Limiting Values (Maximum Value Allowed in the Event of a Failure; also see Figure 4)
Case Temperature
Side 1 Current
Side 2 Current
Insulation Resistance at TS, VIO = 500 V
Symbol Characteristic Unit
VIORM
VPR
I-IV
I-III
I-II
40/105/21
2
560
1050
V peak
V peak
VPR
896
V peak
672
V peak
VTR
4000
V peak
TS
150
°C
IS1
265
mA
IS2
335
mA
RS
>109
Ω
These isolators are suitable for basic electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The * marking on packages denotes DIN EN 60747-5-2 approval.
350
300
250
SIDE #2
200
150
SIDE #1
100
50
0
0
50
100
150
200
CASE TEMPERATURE (°C)
Figure 4. Thermal Derating Curve, Dependence of Safety-Limiting Values
with Case Temperature per DIN EN 60747-5-2
RECOMMENDED OPERATING CONDITIONS
Table 8.
Parameter
Operating Temperature
Supply Voltages1
Input Signal Rise and Fall Times
Symbol Min Max Unit
TA
−40 +105 °C
VDD1, VDD 2 2.7 5.5 V
1.0 ms
1 All voltages are relative to their respective ground. See the DC Correctness
and Magnetic Field Immunity section for information on immunity to
external magnetic fields.
Rev. 0 | Page 13 of 24