0
–10
NO LOAD
–20
–30
–40
10k LOAD
–50
–60
–70
3 4 5 6 7 8 9 10 11 12 13
SUPPLY VOLTAGE (V)
Figure 12. Output Minus Supply vs. Supply Voltage
OUTPUT
INPUT
1
2
CH1 500mVΩ CH2 50mVΩ M 20μs 2.5MS/s 400NS/PT
A CH1 1.73V
Figure 13. Pulse Response
1000
800
600
400
200
0
–200
–400
–600
+25°C
+85°C
–40°C
–800
+125°C
–1000
–10 –5
0
5
10
15
20
25
30
COMMON-MODE VOLTAGE (V)
Figure 14. VOS vs. Common-Mode Voltage
AD8202
18
TEMPERATURE = 25°C
16
14
12
10
8
6
4
2
0
CMRR (μV/V)
Figure 15. CMRR Distribution, −8 V to +28 V Common Mode
8
VSUPPLY = 5V
TEMPERATURE RANGE =
7
–40°C TO +25°C
6
5
4
3
2
1
0
VOS DRIFT (μV/°C)
Figure 16. Offset Drift Distribution, MSOP,
Temperature Range = −40°C to +25°C
12
VSUPPLY = 5V
TEMPERATURE RANGE =
10
25°C TO 125°C
8
6
4
2
0
VOS DRIFT (μV/°C)
Figure 17. Offset Drift Distribution, MSOP,
Temperature Range = 25°C to 125°C
Rev. D | Page 7 of 20