AC Electrical Characteristics
Symbol
tPLH, tPHL
Parameter
Propagation Delay
Time, Data to
Output
tPZH, tPZL Output Enable Time
tPHZ, tPLZ Output Disable
Time
tOSHL, tOSLH Output to Output
Skew(3)
VCC (V)
2.7
3.3 ± 0.3
2.7
3.3 ± 0.3
2.7
3.3 ± 0.3
2.7
3.3
Conditions
CL = 15pF
CL = 50pF
CL = 15pF
CL = 50pF
CL = 15pF, RL = 1kΩ
CL = 50pF, RL = 1kΩ
CL = 15pF, RL = 1kΩ
CL = 50pF, RL = 1kΩ
CL = 50pF, RL = 1kΩ
CL = 50pF, RL = 1kΩ
CL = 50pF
TA = +25°C
Min. Typ. Max.
5.8 10.1
8.3 13.6
4.4 6.2
6.9 9.7
5.3 9.3
7.8 12.8
4.0 5.6
6.5 9.1
10.0 15.7
8.3 11.2
1.5
1.5
TA = –40°C
to +85°C
Min. Max. Units
1.0 13.5 ns
1.0 17.0
1.0 8.5
1.0 12.0
1.0 12.5 ns
1.0 16.0
1.0 7.5
1.0 11.0
1.0 19.0 ns
1.0 13.0
1.5 ns
1.5
Note:
3. Parameter guaranteed by design tOSLH = |tPLHm–tPLHn|, tOSHL = |tPHLm–tPHLn|
Capacitance
Symbol
Parameter
TA = +25°C
Min. Typ. Max.
TA = –40°C to
+85°C
Min. Max.
Units
CIN
Input Capacitance
CPD
Power Dissipation Capacitance(4)
4
10
14
10
pF
pF
Note:
4. CPD is defined as the value of the internal equivalent capacitance which is calculated from the operating current
consumption without load.
Average operating current can be obtained by the eqation: ICC(opr.) = -C----P----D----×-4----V-(--p-C---e-C--r--,-×--b---f-i-I-tN--)---×-----I--C----C-
©1994 Fairchild Semiconductor Corporation
74LVX125 Rev. 1.4.0
4
www.fairchildsemi.com