DC Electrical Characteristics for ACT
Symbol
Parameter
VCC
TA 25qC
TA 55qC to 125qC TA 40qC to 85qC
Units
Conditions
(V)
Typ
Guaranteed Limits
VIH
Minimum HIGH Level
4.5
1.5
2.0
2.0
Input Voltage
5.5
1.5
2.0
2.0
VIL
Maximum LOW Level
4.5
1.5
0.8
0.8
Input Voltage
5.5
1.5
0.8
0.8
VOH
Minimum HIGH Level
4.5
4.49
4.4
4.4
Output Voltage
5.5
5.49
5.4
5.4
2.0
V VOUT 0.1V
2.0
or VCC 0.1V
0.8
V VOUT 0.1V
0.8
or VCC 0.1V
4.4
V IOUT 50 PA
5.4
4.5
3.86
3.70
5.5
4.86
4.70
VOL
Maximum LOW Level
4.5
0.001
0.1
0.1
Output Voltage
5.5
0.001
0.1
0.1
3.76
4.76
0.1
0.1
IOH 12
V IOH 24 mA
IOH 24 mA (Note 6)
V IOUT 50 PA
4.5
5.5
IIN
Maximum Input
5.5
Leakage Current
0.36
0.50
0.36
0.50
r0.1
r1.0
0.44
0.44
r1.0
IOL 12 mA
V IOL 24 mA
IOL 24 mA (Note 6)
PA VI VCC, GND
IOZ
ICCT
IOLD
IOHD
ICC
Maximum 3-STATE
5.5
Current
Maximum
5.5
ICC/Input
Minimum Dynamic
5.5
Output Current (Note 7)
5.5
Maximum Quiescent
5.5
Supply Current
r0.25
0.6
4.0
r5.0
1.6
50
50
80.0
r2.5
1.5
75
75
40.0
PA VI VIL, VIH
VO VCC, GND
mA VI VCC 2.1V
mA VOLD 1.65V Max
mA VOHD 3.85V Min
PA VIN VCC
or GND
Note 6: All outputs loaded; thresholds on input associated with output under test.
Note 7: Maximum test duration 2.0 ms, one output loaded at a time.
www.fairchildsemi.com
4