M27V101
Table 9. Programming Mode AC Characteristics (1)
(TA = 25 °C; VCC = 6.25V ± 0.25V; VPP = 12.75V ± 0.25V)
Symbol
Parameter
Test Condition
Min
Max
ILI
Input Leakage Current
VIL ≤ VIN ≤ VIH
± 10
ICC
Supply Current
50
IPP
Program Current
E = VIL
50
VIL
Input Low Voltage
VIH
Input High Voltage
–0.3
2
0.8
VCC + 0.5
VOL
Output Low Voltage
VOH
Output High Voltage TTL
IOL = 2.1mA
IOH = –400µA
0.4
2.4
VID
A9 Voltage
11.5
Note: 1. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP.
12.5
Unit
µA
mA
mA
V
V
V
V
V
Table 10. Programming Mode AC Characteristics (1)
(TA = 25 °C; VCC = 6.25V ± 0.25V; VPP = 12.75V ± 0.25V
Symbol
Alt
Parameter
Test Condition
Min
tAVPL
tAS Address Valid to Program Low
2
tQVPL
tDS Input Valid to Program Low
2
tVPHPL
tVPS VPP High to Program Low
2
tVCHPL
tVCS VCC High to Program Low
2
tELPL
tCES Chip Enable Low to Program Low
2
tPLPH
tPW Program Pulse Width
95
tPHQX
tDH Program High to Input Transition
2
tQXGL
tOES Input Transition to Output Enable Low
2
tGLQV
tOE Output Enable Low to Output Valid
tGHQZ (2)
tDFP Output Enable High to Output Hi-Z
0
tGHAX
tAH
Output Enable High to Address
Transition
0
Note: 1. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP.
2. Sampled only, not 100% tested.
Max Unit
µs
µs
µs
µs
µs
105
µs
µs
µs
100
ns
130
ns
ns
7/15