Doc No.: 44087312
Issued Date: Oct, 20, 2008
Model No.: N140B6 -L02
Approval
Note (4) Definition of Average Luminance of White (LAVE):
Measure the luminance of gray level 63 at 5 points
LAVE = [L (1)+ L (2)+ L (3)+ L (4)+ L (5)] / 5
L (x) is corresponding to the luminance of the point X at Figure in Note (6).
Note (5) Measurement Setup:
The LCD module should be stabilized at given temperature for 15 minutes to avoid abrupt
temperature change during measuring. In order to stabilize the luminance, the measurement
should be executed after lighting Backlight for 15 minutes in a windless room.
LCD Module
LCD Panel
USB2000
CS-1000T
Center of the Screen
500 mm
Light Shield Room
(Ambient Luminance < 2 lux)
Note (6) Definition of White Variation (δW):
Measure the luminance of gray level 63 at 5 points
δW = Maximum [L (1), L (2), L (3), L (4), L (5)] / Minimum [L (1), L (2), L (3), L (4), L (5)]
Horizontal Line
D
D/4
D/2
3D/4
W/4
W W/2
3W/
1
2
5
3
4
Active Area
22 / 28
X : Test Point
X=1 to 5
Version 2.0