POWER UP/DOWN SEQUENCE
POWER UP/DOWN SEQUENCE
For click free operation, the WM8501 should be powered up and down in a specific sequence.
Power-up:
1. Power up AVDD and DVDD and wait to settle
2. Turn on clocks and data (MCLK, BCLK, LRCLK, SDATA)
3. Switch ENABLE pin from low to high
Power-down:
1. Switch Enable from high to low
2. Remove clocks and data
3. Power down AVDD and DVDD
RECOMMENDED ANALOGUE LOW PASS FILTER
Figure 18 Recommended 1st Order Low Pass Filter
Note: Capacitors should be COG dielectric.
An external single pole RC filter is recommended (see Figure 18) if the device is driving a
wideband amplifier. However the WM8501 does contain an internal low pass filter which should be
adequate in most applications.