ADuM7510
PACKAGE CHARACTERISTICS
Table 2.
Parameter
Resistance (Input-to-Output)1
Capacitance (Input-to-Output)2
Input Capacitance2
IC Junction-to-Ambient Thermal Resistance, QSOP
Symbol
RI-O
CI-O
CI
θJA
Min Typ Max Unit
1012
Ω
2.2
pF
4.0
pF
76
°C/W
Test Conditions
f = 1 MHz
Thermocouple located at center of
package underside
1 The device is considered a 2-terminal device. Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2 Input capacitance is from any input data pin to ground.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 3.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap QSOP Package (Clearance)
Minimum External Tracking QSOP Package (Creepage)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Maximum Working Voltage Compatible with 50 Years
Service Life
Symbol
L(I01)
L(I02)
CTI
VIORM
Value
1000
3.8 min
3.8 min
>400
II
354
Unit Conditions
V rms 1 minute duration
mm Measured from input terminals to output terminals,
shortest distance through air
mm Measured from input terminals to output terminals,
shortest distance path along body
V
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
V peak Continuous peak voltage across the isolation barrier
RECOMMENDED OPERATING CONDITIONS
All voltages are relative to their respective ground. See the DC Correctness and Magnetic Field Immunity section for information on
immunity to external magnetic fields.
Table 4.
Parameter
Operating Temperature
Supply Voltages
Input Signal Rise and Fall Times
Symbol
TA
VDD1, VDD2
Min
Max
Unit
−40
+105
°C
4.5
5.5
V
1.0
ms
REGULATORY INFORMATION
The ADuM7510 is approved by the organization listed in Table 5.
Table 5.
UL (Pending)
Recognized under UL 1577 component recognition program1
Single/basic insulation, 1000 V rms isolation voltage
File E214100
1 In accordance with UL 1577, each ADuM7510 is proof tested by applying an insulation test voltage of 1200 V rms for 1 sec (current leakage detection limit = 5 μA).
Rev. A | Page 4 of 12