Specifications HA-2842/883
TABLE 1. DC ELECTRICAL PERFORMANCE CHARACTERISTICS (Continued)
Device Tested at: VSUPPLY = ±15V, RSOURCE = 100Ω, RLOAD = 100kΩ, VOUT = 0V, Unless Otherwise Specified.
PARAMETERS
SYMBOL
CONDITIONS
GROUP A
SUBGROUP TEMPERATURE
LIMITS
MIN MAX
UNITS
Output Voltage Swing
+VOUT
RL = 1kΩ
1
+25oC
10
-
V
2, 3
+125oC, -55oC
10
-
V
-VOUT
RL = 1kΩ
1
+25oC
-
-10
V
2, 3
+125oC, -55oC
-
-10
V
Output Current
+IOUT
VOUT = -5V
Note 1
1
+25oC
100
-
mA
2, 3
+125oC, -55oC
100
-
mA
-IOUT
VOUT = +5V
Note 1
1
+25oC
-
-100
mA
2, 3
+125oC, -55oC
-
-100
mA
Quiescent Power
Supply Current
+ICC
VOUT = 0V
IOUT = 0mA
1
+25oC
-
15
mA
2, 3
+125oC, -55oC
-
15
mA
-ICC
VOUT = 0V
IOUT = 0mA
1
+25oC
-15
-
mA
2, 3
+125oC, -55oC
-15
-
mA
Power Supply
Rejection Ratio
+PSRR
∆VSUPPLY = 10V
V+ = 10V, V- = -15V
V+ = 20V, V- = -15V
1
+25oC
70
-
dB
2, 3
+125oC, -55oC
70
-
dB
-PSRR
∆VSUPPLY = 10V
V+ = 15V, V- = -10V
V+ = 15V, V- = -20V
1
+25oC
70
-
dB
2, 3
+125oC, -55oC
70
-
dB
Offset Voltage
Adjustment
+VIOAdj
+VIOAdj
Note 2
Note 2
1
+25oC
VIO-1
-
mV
1
+25oC
VIO+1
-
mV
NOTES:
1. Maximum power dissipation, including output load conditions, must be designed to maintain the maximum junction temperature below
+175oC. For a 100mA load and a +125oC ambient, heat sinking is required.
2. Offset Adjustment range is VIO (measured) ±1mV minimum referred to output. This test is for functionality only, to assure adjustment
through 0V.
TABLE 2. AC ELECTRICAL PERFORMANCE CHARACTERISTICS
Table 2 Intentionally Left Blank. See A.C. Specifications in Table 3.
3-232
Spec Number 511088-883