AD549
Data Sheet
Parameter
FREQUENCY RESPONSE
Unity Gain, Small Signal
Full Power Response
Slew Rate
Settling Time, 0.1%
Settling Time, 0.01%
Overload Recovery, 50%
Overdrive, G = −1
POWER SUPPLY
Rated Performance
Operating
Quiescent Current
TEMPERATURE RANGE
Operating, Rated
Performance
Storage
AD549J
AD549K
AD549L
AD549S
Min Typ
Max Min Typ
Max Min Typ
Max Min Typ
Max Unit
0.7 1.0
0.7 1.0
0.7 1.0
0.7 1.0
MHz
50
50
50
50
kHz
23
23
23
23
V/μs
4.5
4.5
4.5
4.5
μs
5
5
5
5
μs
2
2
2
2
μs
±15
±5
0.60
0
−65
±15
±18 ±5
0.70
0.60
70 0
+150 −65
±15
±18 ±5
0.70
0.60
70 0
+150 −65
±15
±18 ±5
0.70
0.60
70 −55
+150 −65
V
±18 V
0.70 mA
+125 °C
+150 °C
1 Bias current specifications are guaranteed after five minutes of operation at TA = 25°C. Bias current increases by a factor of 2.3 for every 10°C rise in temperature.
2 Input offset voltage specifications are guaranteed after five minutes of operation at TA = 25°C.
3 Defined as maximum continuous voltage between the inputs, such that neither input exceeds ±10 V from ground.
Rev. K | Page 4 of 18