Smart battery protection and monitoring IC
M61040FP
6) Power save function
M61040FP contains power save function to control several supply current.
The function and control method are shown as table 2.
The function of battery voltage detection circuit, Charge/Discharge detection circuit, Over current
detection circuit can be stopped as the need arises.
Control method
Battery voltage
detection circuit
Table 2
Charge/Discharge
detection circuit
Over current
detection circuit
Software control
(through Serial I/F)
Ο
Ο
Ο
Each function can be ON/OFF separately.
Enter Power Down Mode
Microcomputer issues shot-down command to M61040 after microcomputer detects that battery
voltage is too low. After this command, the DFOUT pin is set to `high` and the Vin_12pin is pulled
down by internal resistor to be set `low` and series regulator are turned off.
In the power down mode, the M61040 operation is impossible. And CFOUT, DFOUT and PFOUT
pins are set to `high`. (In this situation, both charging and discharging are forbidden. )
At this time, supply current becomes max. 1.0µA , so drops of battery voltage is prevented.