General Description
The MAX3053 interfaces between the control area network (CAN) protocol controller and the physical wires of the bus lines in a CAN. It is primarily intended for industrial systems requiring data rates up to 2Mbps and features ±80V fault protection against shorts to high-voltage power buses. The device provides differential transmit capability to the bus and differential receive capability to the CAN controller.
FEATUREs
● ±80V Fault Protection
● Three Operating Modes
• High-Speed Operation up to 2Mbps
• Slope Control Mode to Reduce EMI
(40kbps to 500kbps)
● 15μA Low-Current Shutdown Mode
● Autoshutdown when Device Is Inactive
● Automatic Wakeup from Shutdown
● Thermal Shutdown
● Current Limiting
● Fully Compatible with the ISO 11898 Standard
APPLICATIONs
● Industrial Control and Networks
● Printers
● HVAC Controls
● Telecom 72V Systems