INTRODUCTION
In a large number of applications, we find the circuit in Fig. 1 where a TRANSIL™ is used to protect a switch that controls an inductive load. The switch can be a bipolar or a MOS transistor.
The purpose of this paper is to calculate the dissipated power in the TRANSIL™ and the pulse current duration.