Maxim Integrated
DESCRIPTION
The DS60 analog temperature sensor measures its own temperature and provides these measurements to the user in the form of an output voltage (VO) that is proportional to degrees centigrade. The output voltage characteristic is factory-calibrated for a typical sensitivity of +6.25mV/°C and a DC offset of +424mV at 0°C. Its operating temperature range is -40°C to +125°C, corresponding to an output voltage range of +174mV to +1205mV. The DS60 has ±2.0°C accuracy over a 0°C to +85°C temperature range and over the full +2.7V to +5.5V power supply range. Its accuracy is within ±3.0°C over the operating temperature range and full supply range. Because the output voltage is positive for the entire temperature range, there is no need for a negative power supply.
BenefitS AND FEATURES
• Minimizes Power Consumption with Low 125µA Supply Current
• Minimizes Board Space with a SOT23 Package
• Maximizes System Accuracy with a Broad Range of Thermal Management Applications
o -40°C to +125°C Measurement Range
o Factory Calibrated for +6.25mV/°C Sensitivity with 424mV DC Offset at 0°C
o ±2.0°C Accuracy Over 0°C to +85°C Range
o Wide Power Supply Range (+2.7V ≤ VDD ≤ +5.5V)
• Functionally-Compatible with LM60
• Applications Include Monitoring Battery Packs, Disk Drives, Printers, Space- or Power-Constrained Thermally Sensitive Systems