datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

NC2EBD-AC48V 데이터 시트보기 (PDF) - Panasonic Corporation

부품명
상세내역
제조사
NC2EBD-AC48V Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
SAFETY STANDARDS
Product name
2 Form C
File No.
E43028
NC
E43028
4 Form C
NC Amber
2 Form C
4 Form C
E43028
E43028
UL/C-UL (Recognized)
Contact rating
5A 250V AC
1/10HP 125, 250V AC
5A 30V DC
5A 125V AC
4A 250V AC
1/10HP 125, 250V AC
5A 30V DC
3A 250V AC
1/20HP 125, 250V AC
5A 30V DC
2A 250V AC
1/20HP 125, 250V AC
5A 30V DC
NC
File No.
LR26550
etc.
LR26550
etc.
LR26550
etc.
LR26550
etc.
CSA (Certified)
Contact rating
5A 250V AC
1/10HP 125, 250V AC
5A 30V DC
5A 125V AC
4A 250V AC
1/10HP 125, 250V AC
5A 30V DC
3A 250V AC
1/20HP 125, 250V AC
5A 30V DC
2A 250V AC
1/20HP 125, 250V AC
5A 30V DC
NOTES
1. Because the NC relay is polarized, the
positive “+” and negative “–” connections
to the coil should be done as indicated on
the wiring diagram. If connected
incorrectly, it may malfunction or fail to
operate.
2. While NC relays can be used with any
transmission-wave current to their
operation, due to slight weakening of the
force of magnetic attraction, decreased
resistance to vibration and shock should
be taken into account.
3. The current that energizes the coil in
an NC relay is AC type. Because the AC
sine waveform is distorted, when testing,
it is essential to use a measuring device
that can properly characterize the
distorted waveform.
The operating power of the coil in the 100
V AC 4 Form C type is relatively higher
than other NC types of AC relay and
consequently, the total current applied
through all the contacts should be kept
below 10 A.
4. The AC type NC relay has a special
magnetic design. As a result, once the a-
side contacts have switched, the b-side
contacts may once again go into a
temporary ON state depending on the
coil inrush phase. To ensure that this
phenomenon does not occur, it is
necessary to carry out sufficient practical
testing with relays installed in actual
devices.
5. When designing top and bottom view
schematic diagrams, note that:
1) “Top view” wiring diagram is indicated
for the flat series because terminals can
be seen from above.
2) “Bottom view” schematic diagram is
indicated for the vertical series because
terminals cannot be seen from above.
Top view
Vertical series
Flat series
Bottom view
(Same direction)
For Cautions for Use.
6. Cautions for close proximity mounting
When using slim series in close proximity,
mount all relays facing the same
direction. Different mounting directions
may cause change in the relay
characteristics because NC relays are
polarized.
ASCTB12E 201209-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]