POWERLINE
DC/DC-Converter
RP10-S_DEW
Series
Specifications (typical at nominal input and 25°C unless otherwise noted)
Vibration
Relative Humidity
Case Material
Base Material
Potting Material
Conducted Emissions (see Note 10)
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Weight
Dimensions
MTBF (see Note 2)
10-55Hz, 2G, 30 Min. along X, Y and Z
5% to 95% RH
Nickel plated copper
Non-conductive black plastic
Epoxy (UL94-V0)
Level A
Level A
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
27g
50.8 x 25.4 x 10.2mm
1976 x 103 hours
Notes :
1. The RP10 (W) series required a minimum 10% loading on the output to maintain specified regulation.
Operation under no-load condition will not damage these devices, however they may not meet all listedspecification.
2. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment).
3. Simulated source impedance of 12µH. 12µH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input.
Positive logic ON/OFF is marked with suffix-P (eg. RP10-2405SEW/P)
Negative logic ON/OFF is marked with suffix-N (eg. RP10-2405SEW/N).
If no suffix is specified, the control pin will be omitted.
8. Heat sink is optional and P/N: 7G-0020A.
9. M2 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard version.
10. See application notes for EMI-filtering.
www.recom-international.com
July-2006
227