Data Sheet
AD7175-8
STATUS REGISTER
Address: 0x00, Reset: 0x80, Name: STATUS
The status register is an 8-bit register that contains ADC and serial interface status information. It can optionally be appended to the data
register by setting the DATA_STAT bit in the interface mode register.
Table 26. Bit Descriptions for STATUS
Bits Bit Name
Settings
7
RDY
0
1
6
ADC_ERROR
0
1
5
CRC_ERROR
0
1
4
REG_ERROR
0
1
[3:0] CHANNEL
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Description
The status of RDY is output to the DOUT/RDY pin whenever CS is low and
a register is not being read. This bit goes low when the ADC has written a
new result to the data register. In ADC calibration modes, this bit goes low
when the ADC has written the calibration result. RDY is brought high
automatically by a read of the data register.
New data result available
Awaiting new data result
This bit by default indicates if an ADC overrange or underrange has
occurred. The ADC result is clamped to 0xFFFFFF for overrange errors and
0x000000 for underrange errors. This bit is updated when the ADC result is
written and is cleared at the next update after removing the overrange or
underrange condition.
No error
Error
This bit indicates if a CRC error has taken place during a register write. For
register reads, the host microcontroller determines if a CRC error has
occurred. This bit is cleared by a read of this register.
No error
CRC error
This bit indicates if the content of one of the internal registers has
changed from the value calculated when the register integrity check was
activated. The check is activated by setting the REG_CHECK bit in the
interface mode register. This bit is cleared by clearing the REG_CHECK bit.
No error
Error
These bits indicate which channel was active for the ADC conversion
whose result is currently in the data register. This may be different from
the channel currently being converted. The mapping is a direct map from
the channel register; therefore, Channel 0 results in 0x0 and Channel 15
results in 0xF.
Channel 0
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
Channel 9
Channel 10
Channel 11
Channel 12
Channel 13
Channel 14
Channel 15
Reset
0x1
0x0
0x0
0x0
0x0
Access
R
R
R
R
R