Si3000PPT-EVB
Figure 5. Transhybrid Loss
Transhybrid Loss Calculation
When “Transhybrid Loss Calculation” is selected, the
Si30xxPPT-EVB software will drive a signal with
different frequencies and measure the transhybrid loss
based on the following equation: Transhybrid Loss =
20Log(TXpk-pk/RXpk-pk). Frequencies used to
measure this start from 100 Hz to 4000 Hz in 20 Hz
steps.
Ringing
This function is not availabe on the Si3000PPT-EVB.
10