TLE 4279
Characteristics
VI = 13.5 V; Tj = – 40 °C < Tj < 125 °C
Parameter
Symbol
Limit Values Unit
min. typ. max.
Measuring
Condition
Output voltage
VQ
Current limit
IQ
Current consumption; Iq
Iq = II – IQ
Current consumption; Iq
Iq = II – IQ
Current consumption; Iq
Iq = II – IQ
Drop voltage
Vdr
Load regulation
∆VQ
Line regulation
∆VQ
Reset Generator
4.90 5.00 5.10 V
150 200 500 mA
–
150 300 µA
1 mA ≤ IQ ≤ 100 mA
6 V ≤ VI ≤ 16 V
–
IQ ≤ 1 mA, Tj < 85 °C
–
250 700 µA IQ = 10 mA
–2
8
mA IQ = 50 mA
–
0.25 0.5 V
IQ = 100 mA1)
–
10 30 mV IQ = 5 mA to 100 mA
–
10 40 mV VI = 6 V to 26 V
IQ = 1 mA
Switching threshold
VRT
4.50 4.65 4.80 V
Reset adjust switching VRADJ,TH 1.26 1.35 1.44 V
voltage
–
VQ > 3.5 V
Reset low voltage
VRO,SAT
–
0.1 0.4 V
Upper delay switching VUD
threshold
1.4 1.8 2.2 V
Rextern = 20 kΩ
–
Lower delay switching VLD
threshold
0.3 0.45 0.60 V
–
Reset delay low voltage VD,SAT
–
–
0.1 V
VQ < VRT
1) Drop voltage = VI – VQ (measured when the output voltage has dropped 100 mV
from the nominal value obtained at 13.5 V input.)
Data Sheet Rev. 2.3
8