Data Sheet, Rev. 1
June 2001
FW801A Low-Power PHY IEEE 1394A-2000
One-Cable Transceiver/Arbiter Device
Signal Information (continued)
Table 1. Signal Descriptions
Pin
Signal*
Type
Name/Description
17
C/LKON
I/O Bus Manager Capable Input and Link-On Output. On hardware reset,
this pin is used to set the default value of the contender status indicated
during self-ID. The bit value programming is done by tying the signal
through a 10 kresistor to VDD (high, bus manager capable) or to GND
(low, not bus manager capable). Using either the pull-up or pull-down
resistor allows the link-on output to override the input value when neces-
sary.
After hardware reset, this pin is set as an output. If the LPS is inactive,
C/LKON indicates one of the following events by asserting a 6.114 MHz
signal.
13
CNA
20
CPS
1
2
3, 4, 6, 7,
8, 9, 10,
11
19
CTL0
CTL1
D[0:7]
/ISO
1. FW801A receives a link-on packet addressed to this node.
2. Port_event register bit is 1.
3. Any of the Timeout, Pwr_Fail, or Loop register bits are 1 and the
Resume_int register bit is also 1. Once activated, the C/LKON output will
continue active until the LPS becomes active. The PHY also deasserts
the C/LKON output when a bus reset occurs, if the C/LKON is active due
solely to the reception of a link-on packet.
Note: If an interrupt condition exists which would otherwise cause the C/
LKON output to be activated if the LPS were inactive, the C/LKON
output will be activated when the LPS subsequently becomes inac-
tive.
O
Cable-Not-Active Output. CNA is asserted high when none of the PHY
ports are receiving an incoming bias voltage. This circuit remains active
during the powerdown mode.
I
Cable Power Status. CPS is normally connected to the cable power
through a 400 kresistor. This circuit drives an internal comparator that
detects the presence of cable power. This information is maintained in
one internal register and is available to the LLC by way of a register read
(see Table 8, Register 0).
I/O Control I/O. The CTLn signals are bidirectional communications control
signals between the PHY and the LLC. These signals control the passage
of information between the two devices. Bus-keeper circuitry is built into
these terminals.
I/O Data I/O. The Dn signals are bidirectional and pass data between the
PHY and the LLC. Bus-keeper circuitry is built into these terminals.
I
Link Interface Isolation Disable Input (Active-Low). /ISO controls the
operation of an internal pulse differentiating function used on the PHY-
LLC interface signals, CTLn and Dn, when they operate as outputs. When
/ISO is asserted low, the isolation barrier is implemented between PHY
and its LLC (as described in Annex J of IEEE 1394-1995). /ISO is nor-
mally tied high to disable isolation differentiation. Bus-keepers are
enabled when /ISO is high (inactive) on CTL, D, and LREQ. When /
ISO is low (active), the bus-keepers are disabled. Please refer to Agere’s
application note AP98-074CMPR for more information on isolation.
* Active-low signals are indicated by “/” at the beginning of signal names, within this document.