Nexperia
74LV4052
Dual 4-channel analog multiplexer/demultiplexer
9. Static characteristics
Table 6. Static characteristics
At recommended operating conditions. Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
40 C to +85 C
Min Typ[1] Max
VIH
HIGH-level input voltage VCC = 1.2 V
0.9
-
-
VCC = 2.0 V
1.4
-
-
VCC = 2.7 V to 3.6 V
2.0
-
-
VCC = 4.5 V
3.15
-
-
VCC = 6.0 V
4.20
-
-
VIL
LOW-level input voltage VCC = 1.2 V
-
-
0.3
VCC = 2.0 V
-
-
0.6
VCC = 2.7 V to 3.6 V
-
-
0.8
VCC = 4.5 V
-
-
1.35
VCC = 6.0 V
-
-
1.80
II
input leakage current
VI = VCC or GND
VCC = 3.6 V
-
-
1.0
VCC = 6.0 V
-
-
2.0
IS(OFF) OFF-state leakage current VI = VIH or VIL; see Figure 7
VCC = 3.6 V
-
-
1.0
VCC = 6.0 V
-
-
2.0
IS(ON) ON-state leakage current VI = VIH or VIL; see Figure 8
VCC = 3.6 V
-
-
1.0
VCC = 6.0 V
-
-
2.0
ICC
supply current
VI = VCC or GND; IO = 0 A
VCC = 3.6 V
-
-
20
VCC = 6.0 V
-
-
40
ICC additional supply current per input; VI = VCC 0.6 V;
-
-
500
VCC = 2.7 V to 3.6 V
CI
input capacitance
-
3.5
-
Csw
switch capacitance
independent pins nYn
-
5
-
common pins nZ
-
12
-
40 C to +125 C Unit
Min
Max
0.9
-V
1.4
-V
2.0
-V
3.15
-V
4.20
-V
-
0.3 V
-
0.6 V
-
0.8 V
-
1.35 V
-
1.80 V
-
1.0 A
-
2.0 A
-
1.0 A
-
2.0 A
-
1.0 A
-
2.0 A
-
40 A
-
80 A
-
850 A
-
- pF
-
- pF
-
- pF
[1] Typical values are measured at Tamb = 25 C.
74LV4052
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 5 — 17 March 2016
© Nexperia B.V. 2017. All rights reserved
7 of 25