Nexperia
74LV4052
Dual 4-channel analog multiplexer/demultiplexer
8. Recommended operating conditions
Table 5.
Symbol
VCC
VI
VSW
Tamb
t/V
Recommended operating conditions[1]
Parameter
Conditions
supply voltage
see Figure 6
input voltage
switch voltage
ambient temperature
in free air
input transition rise and fall rate VCC = 1.0 V to 2.0 V
VCC = 2.0 V to 2.7 V
VCC = 2.7 V to 6.0 V
Min
Typ
Max Unit
1
3.3
6V
0
-
VCC V
0
-
VCC V
40
-
+125 C
-
-
500 ns/V
-
-
200 ns/V
-
-
100 ns/V
[1] The static characteristics are guaranteed from VCC = 1.2 V to 6.0 V. However, LV devices are guaranteed to function down to
VCC = 1.0 V (with input levels GND or VCC).
9&&*1'
9
DDN
RSHUDWLQJDUHD
9&&9((9
Fig 6. Guaranteed operating area as a function of the supply voltages
74LV4052
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 5 — 17 March 2016
© Nexperia B.V. 2017. All rights reserved