AC Electrical Characteristics (Note 8)
TA = −40°C to +85°C, CL = 30 pF, RL = 500Ω
Symbol
Parameter
VCC = 3.3V ± 0.3V
VCC = 2.5 ± 0.2V
VCC = 1.8 ± 0.15V
Units
Min
Max
Min
Max
Min
Max
fMAX
Maximum Clock Frequency
250
200
100
MHz
tPHL, tPLH
Propagation Delay Clock to Bus
1.3
3.6
1.5
4.6
2.0
9.2
ns
tPZL, tPZH
Output Enable Time
0.6
3.5
0.8
4.5
1.5
9.0
ns
tPLZ, tPHZ
Output Disable Time
0.6
3.2
0.8
4.2
1.5
7.6
ns
tS
Setup Time
2.0
2.0
3.0
ns
tH
Hold Time
0.0
0.0
0.5
ns
tW
Pulse Width
1.5
1.5
4.0
ns
tOSHL
tOSLH
Output to Output Skew
(Note 9)
0.5
0.5
0.75
ns
Note 8: For CL= 50 pF, add approximately 300 ps to the AC maximum specification.
Note 9: Skew is defined as the absolute value of the difference between the actual propagation delay for any two separate outputs of the same device. The
specification applies to any outputs switching in the same direction, either HIGH-to-LOW (tOSHL) or LOW-to-HIGH (tOSLH).
AC Electrical Characteristics Over Load (Note 10)
TA = −0°C to +70°C, RL = 500Ω VCC = 3.3V ± 0.3V
Symbol
Parameter
CL = 0 pF
CL = 50 pF
Min
Max
Min
Max
tPHL, tPLH
Propagation Delay Clock to Bus
1.1
2.5
1.9
3.9
tPZL, tPZH
Output Enable Time
0.7
2.4
1.0
3.8
tPLZ, tPHZ
Output Disable Time
0.7
2.1
1.0
3.5
tS
Setup Time
2.0
2.0
tH
Hold Time
0.0
0.0
tW
Pulse Width
1.5
1.5
Note 10: This parameter is guaranteed by characterization but not tested.
Units
ns
ns
ns
ns
ns
ns
Dynamic Switching Characteristics
Symbol
VOLP
Parameter
Conditions
Quiet Output Dynamic Peak VOL CL = 30 pF, VIH = VCC, VIL = 0V
VOLV
Quiet Output Dynamic Valley VOL CL = 30 pF, VIH = VCC, VIL = 0V
VOHV
Quiet Output Dynamic Valley VOH CL = 30 pF, VIH = VCC, VIL = 0V
VCC
TA = +25°C
Units
(V)
Typical
1.8
0.25
2.5
0.6
V
3.3
0.8
1.8
−0.25
2.5
−0.6
V
3.3
−0.8
1.8
1.5
2.5
1.9
V
3.3
2.2
5
www.fairchildsemi.com