NCP1654
Soft Start
The block diagram and timing diagram of soft start
function are as shown in Figure 42 and Figure 43. The
device provides no output (or no duty ratio) when the
Vcontrol is lower than VCONTROL(min). Vcontrol is pulled low
when:
• Brown−out, or
• Undervoltage Protection
When the IC recovers from one of the following
conditions; Undervoltage Lockout, Brown−out or
Undervoltage Protection, the 200 mA current source block
keeps off. Hence only the Operating Trans−conductance
Amplifier (OTA) raises the Vcontrol. And Vcontrol rises
slowly. This is to obtain a slow increasing duty cycle and
hence reduce the voltage and current stress on the
MOSFET. A soft−start operation is obtained.
Vdd
Off
Bias
BO UVLO UVP
SQ
RQ
Vdd
200 mA
Vfb
6
Vcontrol
5
-
95%
+
VREF
-
Vout Low Detect
±20 mA
VREF
+ OTA
BO UVLO
UVLO, BO, or UVP
Vdd
Vdd Rising
Vfb
Vout Low Detect
Set
Reset
Q
Period I
Figure 42. Soft Start Block Diagram
Period II
95% VREF
Figure 43. Soft Start Timing Diagram