Industrial Version
PLCC DC Electrical Characteristics (Note 7)
VEE = −4.2V to −5.7V, VCC = VCCA = GND, TC = −40°C to +85°C
Symbol
Parameter
TC = −40°C
Min
Max
TC = 0°C to +85°C
Min
Max
Units
Conditions
VOH
Output HIGH Voltage
VOL
Output LOW Voltage
−1085
−1830
−870
−1575
−1025
−1830
−870
−1620
mV
VIN = VIH(Max)
or VIL(Min)
Loading with
50Ω to −2.0V
VOHC
VOLC
Output HIGH Voltage
Output LOW Voltage
−1095
−1565
−1035
−1610
mV
VIN = VIH(Min)
or VIL(Max)
Loading with
50Ω to −2.0V
VIH
Input HIGH Voltage
−1170 −870 −1165 −870
mV Guaranteed HIGH Signal for ALL Inputs
VIL
Input LOW Voltage
−1830 −1480 −1830 −1475
mV Guaranteed LOW Signal for ALL Inputs
IIL
Input LOW Current
0.05
0.05
µA VIN = VIL(Min)
IIH
Input HIGH Current
300
240
µA VIN = VIH(Max)
IEE
Power Supply Current
−45
−20
−45
−20
mA Inputs OPEN
Note 7: The specified limits represent the “worst case” value for the parameter. Since these values normally occur at the temperature extremes, additional
noise immunity and guardbanding can be achieved by decreasing the allowable system operating ranges. Conditions for testing shown in the tables are cho-
sen to guarantee operation under the “worst case” conditions.
PLCC AC Electrical Characteristics
VEE = −4.2V to −5.7V, VCC = VCCA = GND
Symbol
Parameter
TC = −40°C
Min
Max
TC = +25°C
Min
Max
TC = +85°C
Min
Max
Units
tPLH
Propagation Delay
tPHL
Data to Output
0.40
1.05
0.50
1.05
0.50
1.15
ns
tPLH
Propagation Delay
tPHL
Enable to Output
0.70
1.80
0.70
1.80
0.80
1.90
ns
tTLH
Transition Time
tTHL
20% to 80%, 80% to 20%
0.30
1.10
0.40
1.10
0.40
1.10
ns
Note 8: The propagation delay specified is for single output switching. Delays may vary up to 200 ps with multiple outputs switching.
Conditions
Figures 1, 2
(Note 8)
Figures 1, 2
5