NXP Semiconductors
74LVC1G74-Q100
Single D-type flip-flop with set and reset; positive edge trigger
9. Recommended operating conditions
Table 7.
Symbol
VCC
VI
VO
Operating conditions
Parameter
supply voltage
input voltage
output voltage
Tamb
t/V
ambient temperature
input transition rise and fall rate
10. Static characteristics
Conditions
Active mode
Power-down mode; VCC = 0 V
VCC = 1.65 V to 2.7 V
VCC = 2.7 V to 5.5 V
Min
Max
Unit
1.65
5.5
V
0
5.5
V
0
VCC
V
0
5.5
V
40
+125
C
-
20
ns/V
-
10
ns/V
Table 8. Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
Typ[1]
Tamb = 40 C to +85 C
VIH
HIGH-level input voltage VCC = 1.65 V to 1.95 V
0.65 VCC -
VCC = 2.3 V to 2.7 V
1.7
-
VCC = 2.7 V to 3.6 V
2.0
-
VCC = 4.5 V to 5.5 V
0.7 VCC -
VIL
LOW-level input voltage VCC = 1.65 V to 1.95 V
-
-
VCC = 2.3 V to 2.7 V
-
-
VCC = 2.7 V to 3.6 V
-
-
VCC = 4.5 V to 5.5 V
-
-
VOH
HIGH-level output voltage VI = VIH or VIL
IO = 100 A; VCC = 1.65 V to 5.5 V
IO = 4 mA; VCC = 1.65 V
IO = 8 mA; VCC = 2.3 V
IO = 12 mA; VCC = 2.7 V
IO = 24 mA; VCC = 3.0 V
IO = 32 mA; VCC = 4.5 V
VCC 0.1 -
1.2
1.54
1.9
2.15
2.2
2.50
2.3
2.62
3.8
4.11
VOL
LOW-level output voltage VI = VIH or VIL
IO = 100 A; VCC = 1.65 V to 5.5 V
-
IO = 4 mA; VCC = 1.65 V
-
-
0.07
IO = 8 mA; VCC = 2.3 V
-
0.12
IO = 12 mA; VCC = 2.7 V
-
0.17
IO = 24 mA; VCC = 3.0 V
-
0.33
IO = 32 mA; VCC = 4.5 V
II
input leakage current
VI = 5.5 V or GND;
VCC = 0 V to 5.5 V
IOFF
power-off leakage current VI or VO = 5.5 V; VCC = 0 V
-
0.39
-
0.1
-
0.1
Max
Unit
-
V
-
V
-
V
-
V
0.35 VCC V
0.7
V
0.8
V
0.3 VCC V
-
V
-
V
-
V
-
V
-
V
-
V
0.10
V
0.45
V
0.30
V
0.40
V
0.55
V
0.55
V
5
A
10
A
74LVC1G74_Q100
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 2 — 14 May 2013
© NXP B.V. 2013. All rights reserved.